Biostatistics Research - Statistics, Uncertainty, Probability, Modeling

Biostatistics Research Today is a free monthly online journal that collates and summarizes the latest research about Biostatistics, including details on statistics, uncertainty, probability, modeling.


Biostatistics Research Today

Home

View Latest Issue

Information About Biostatistics

Books on Biostatistics

Advertising in Research Today

View Other Research Today Publications



Biometric calculation of intraocular lens power for cataract surgery following pupil dilatation.

Bansal S, Quah SA, Turpin T, Batterbury M

Department of Ophthalmology, St James' University Hospital, Leeds, UK. shveta.ophth@gmail.com

BACKGROUND: The ability to perform biometry accurately on a dilated pupil can greatly facilitate the efficiency of a cataract service as it can be done on the day of surgery. The purpose of this study was to assess the repeatability of axial length (AL) calculations in undilated pupils and measure the difference in predicted and actual refractive outcomes in dilated pupils compared with undilated pupils. METHODS: First, intraobserver repeatability was assessed by taking two consecutive recordings of AL using applanation A-scan ultrasonography in undilated pupils in 21 eyes. The mean AL for each eye was compared with a measurement made following pupil dilatation. Second, we audited the mean spherical equivalent refractive errors following routine cataract surgery in 38 patients with undilated pupils and 36 patients with dilated pupils. RESULTS: The mean difference in intraobserver measurements was -0.05 mm (standard deviation [SD] 0.15) with pupils undilated. Following pupil dilatation, the mean dilated AL differed from the mean undilated AL reading by only 0.03 mm (P > 0.05). The mean differences between planned and actual refractive error were 0.71D (SD 0.54) and 0.55D (SD 0.41) in dilated and undilated patients, respectively. This was not statistically significant (P > 0.05). The range of differences between target and actual refraction was -1.45D to 2.70D for undilated patients and -1.88D to 1.18D in dilated patients. CONCLUSION: Although there was a greater spread of postoperative refractive errors in the dilated group, there were no statistically or clinically significant differences in postoperative refractive errors between the two categories of patients. Our study shows that applanation biometry may be safely performed for the purpose of cataract surgery after pupil dilatation.

Published 20 March 2008 in Clin Experiment Ophthalmol, 36(2): 156-8.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Biostatistics Research Today. All Rights Reserved.



Biostatistics Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)



Biostatistics Books

Practical Statistics for Medical Research (Statistics Texts)

Practical Statistics for Medical Research (Statistics Texts)