An evaluation of keratometry in 6-year-old children.

Huynh SC, Mai TQ, Kifley A, Wang JJ, Rose KA, Mitchell P

Centre for Vision Research, Department of Ophthalmology and Westmead Millennium Institute, University of Sydney, Sydney, Australia.

PURPOSE: To evaluate the repeatability and comparability of keratometry measured by both the IOLMaster and RK-F1 AutoRef-Keratometer in children. METHODS: Keratometry results from a sample (n = 447) of 6-year-old children who were examined in the Sydney Myopia Study were analyzed. Corneal power was analyzed along the flattest and steepest meridians to determine if there were any systematic differences between repeat measurements or between the two instruments. The 95% limits of repeatability (LR) and 95% limits of agreement (LA) (mean difference +/- 1.96 x standard deviation of differences) were calculated. RESULTS: There were no systematic differences in repeat measurements for each instrument. For the IOLMaster, mean difference of the flattest corneal meridian was -0.01 (D) (P = 0.3, 95% LR, -0.22, 0.21 D) and of the steepest corneal meridian, 0.01 D (P = 0.3, 95% LR, -0.35, 0.38 D). For the RK-F1, mean difference of the flattest corneal meridian was -0.02 D (P = 0.3, 95% LR, -0.25, 0.21 D); and of the steepest corneal meridian, 0.00 D (P = 0.9, 95% LR, -0.39, 0.39 D). Systematic differences, however, were found between the two instruments. The IOLMaster gave significantly (P < 0.0001) steeper readings than the RK-F1 for both the flattest corneal meridian, 0.29 D (95% LA, -0.08, 0.66 D), and the steepest corneal meridian, 0.18 D (95% LA, -0.29, 0.65 D). CONCLUSIONS: Keratometry was highly repeatable for both the IOLMaster and RK-F1 instruments when used in young children. These instruments would be suitable for use in monitoring changes of corneal curvature over time. Small significant systematic differences in keratometry between the two instruments were also found.

Published 3 May 2006 in Cornea, 25(4): 383-7.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Biostatistics Research Today. All Rights Reserved.



Biostatistics Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)



Biostatistics Books

Statistics for Health Policy and Administration Using Microsoft Excel

Statistics for Health Policy and Administration Using Microsoft Excel