Biostatistics Research - Statistics, Uncertainty, Probability, Modeling

Biostatistics Research Today is a free monthly online journal that collates and summarizes the latest research about Biostatistics, including details on statistics, uncertainty, probability, modeling.


Biostatistics Research Today

Home

View Latest Issue

Information About Biostatistics

Books on Biostatistics

Advertising in Research Today

View Other Research Today Publications



Precision of the CAESAR scan-extracted measurements.

Robinette KM, Daanen HA

Air Force Research Laboratory, 2800 Q Street, Bldg 824, Wright-Patterson AFB, OH 45433-7947, USA. kathleen.robinette@wpafb.af.mil

Three-dimensional (3D) body scanners are increasingly used to derive 1D body dimensions from 3D whole body scans for instance, as input for clothing grading systems to make made-to-measure clothing or for width and depth dimensions of a seated workstation. In this study, the precision of the scanner-derived 1D dimensions from the CAESAR survey, a multinational anthropometric survey, was investigated. Two combinations of scanning teams with 3D whole body scanners were compared, one called the US Team and the other the Dutch Team. Twenty subjects were measured three times by one scanner and one team, and three times by the other combination. The subjects were marked prior to scanning using small dots, and the linear distances between the dots were calculated after processing the scans. The mean absolute difference (MAD) of the repetitions was calculated and this was compared to reported acceptable errors in manual measurements from the US Army's ANSUR survey when similar measurements were available. In addition, the coefficient of variation (CV) was calculated for all measurements. The results indicate that the CAESAR scan-extracted measurements are highly reproducible; for most measures the MAD is less than 5mm. In addition, more than 93% of the MAD values for CAESAR are significantly smaller than the ANSUR survey acceptable errors. Therefore, it is concluded that the type of scan-extracted measures used in CAESAR are as good as or better than comparable manual measurements. Scan-extracted measurements that do not use markers or are not straight-line distances are not represented here and additional studies would be needed to verify their precision.

Published 6 February 2006 in Appl Ergon, 37(3): 259-65.
Full-text of this article is available online (may require subscription).

Place a permanent text-link or advertisement here for just US$15.

© 2005-2008 Biostatistics Research Today. All Rights Reserved.



Biostatistics Research Today Archive:

Volume 1 (2005)
  Issue 1 (September)
  Issue 2 (October)
  Issue 3 (November)
  Issue 4 (December)

Volume 2 (2006)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 3 (2007)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)
  Issue 9 (September)
  Issue 10 (October)
  Issue 11 (November)
  Issue 12 (December)

Volume 4 (2008)
  Issue 1 (January)
  Issue 2 (February)
  Issue 3 (March)
  Issue 4 (April)
  Issue 5 (May)
  Issue 6 (June)
  Issue 7 (July)
  Issue 8 (August)



Biostatistics Books

Statistics for Epidemiology

Statistics for Epidemiology